Skip to content
FlowCalc
Browse: Calculators, Guides, How it works
All calculators Guides How it works

Batch Totalizer

Batch total V = Q t and time t = V/Q.

Inputs

Inputs

Result

Time for batch
8.00 h
Total volume
288.0 m3

About this calculator

What this calculator does

This batch calculator assumes a constant volumetric flow during the entered duration. The totalized volume is:

V = Qt

It also solves the same relationship for the time needed to reach a separate batch target: t = Vtarget/Q. Flow must be in m³/h and duration in hours, so the volume output is in m³.

Reading the result

At the defaults, 36 m³/h for 8 h produces 36 × 8 = 288 m³. A 288 m³ target at 36 m³/h also needs 288/36 = 8.00 h. Doubling the flow doubles the volume accumulated in the same time and halves the time required for the same target. Doubling the duration doubles the total volume but does not change the time needed for the separate target.

The totalizer and batch-time outputs use different input paths. You can compare them when the duration and target describe the same batch, but the calculator does not force them to match. A target of 300 m³ at the default flow would require 8.33 h even though the entered 8 h total remains 288 m³.

When to use / when not to use

Use this screen for a constant or average flow estimate, batch planning, and quick capacity checks. If flow changes with time, total volume is the sum of each interval's flow × duration, or the integral of Q(t); split the period into representative segments or use a time-series totalizer. This page does not account for startup delays, shutdowns, dead time, meter bias, or changing density in a mass-flow calculation.

Input and output variables

Q
Constant or average volume flow
t
Duration in hours
V, V_target
Accumulated volume and independent batch target

Worked example

At 36 m3/h for 8 h, total volume is 288 m3. A separate 288 m3 batch target at 36 m3/h requires 8.00 h.

Frequently asked questions

How do I use the Batch Totalizer?

Enter entered inputs with units as labeled, read each output with its substituted formula, then verify against datasheets and field readings before acting.

Is this result final?

Screening only — calibrate C from a known point; custody needs full ISO 5167.

Learn

How to interpret the result

Plan batch volume and time.

Checklist before you rely on it

  1. Confirm units match the input labels before trusting the result.
Screening result for preliminary sizing only. Verify against the manufacturer datasheet and applicable standard before procurement or construction.

Related calculators

Workspace

Save this calculation to your workspace

Save this calculation to your private workspace: keep inputs + result, compare scenarios side by side, and export a report with substituted formulas.

  • Save projects — return to inputs, result, and report.
  • Compare scenarios — see which option holds margin.
  • Export report — PDF/CSV with formulas shown.

Sign in or create an account to save this calculation.