Skip to content
FlowCalc
Browse: Calculators, Guides, How it works
All calculators Guides How it works

Manning Open-Channel Flow (Full Pipe)

Gravity-flow capacity of a full circular pipe.

Inputs

Inputs

Result

Flow Q
429.9 m3/h
Velocity
0.61 m/s

About this calculator

What this calculator does

This calculator estimates the mean velocity and flow rate of a circular conduit flowing full under a uniform gravity-flow condition. It applies Manning’s relation using the diameter, one roughness coefficient, and a slope; it does not solve a pressure-pipe network or a culvert controlled by inlet, outlet, or tailwater conditions.

Pipe flow, geometry, Reynolds number, friction factor, and pressure loss chain
Pipe pressure loss is a chain from flow and geometry through regime and friction model.

Why a full pipe uses D/4

The SI form used here is V = (1/n) R2/3 S1/2, followed by Q = V A. For a full circle, the flow area is A = πD²/4 and the wetted perimeter is P = πD, so the hydraulic radius R = A/P = D/4. It is not the geometric radius D/2. The calculator converts diameter from millimetres to metres, computes velocity in m/s, then multiplies by area and 3,600 to report m³/h.

The slope term is under a square root, so raising slope increases velocity and flow more slowly than the same percentage increase in slope. The roughness coefficient n acts inversely: a larger value represents greater hydraulic resistance and lowers both outputs. FHWA’s culvert design handbook treats Manning’s n as a resistance coefficient and notes that selected values vary with conduit material and condition; this calculator accepts one value and does not combine different wall materials into a composite n.

Example: how the inputs change capacity

At the default diameter of 500 mm, n = 0.013, and S = 0.001 (a 0.1% grade), the full-bore area is about 0.19635 m² and R = 0.125 m. The independently calculated results are:

CaseVelocityFlowChange from default
Default: n = 0.013, S = 0.0010.608 m/s429.86 m³/h—
Double the slope: n = 0.013, S = 0.0020.860 m/s607.92 m³/hAbout 1.414×, because √2 ≈ 1.414
Double n: n = 0.026, S = 0.0010.304 m/s214.93 m³/hHalf, because velocity is proportional to 1/n

Diameter changes both terms: a wider full pipe has more area and a larger hydraulic radius. At fixed n and S, the model therefore predicts velocity proportional to D2/3 and flow proportional to D8/3. If you already know flow and diameter and want to check the implied average velocity from Q = V A, compare with the pipe velocity calculator.

Where this estimate stops

Use the result as a uniform-flow capacity estimate when the pipe is full and the entered slope represents the energy grade driving that flow. A full pipe can still be pressurized, backed up, or governed by inlet and outlet losses; in those cases the pipe’s physical grade alone may not describe the available energy slope. The calculation also omits partial filling, changing water depth, fittings, entrance and exit losses, sediment, and tailwater. Use a culvert or network method that includes those conditions before relying on a design capacity.

Input and output variables

n
Manning roughness
R
Hydraulic radius
S
Slope
V
(1/n)R^2/3 S^1/2

Worked example

Concrete n=0.013, R=0.25 m, S=0.005: V = (1/0.013)*0.396*0.0707 = 2.15 m/s. Multiply by area for full-pipe screening flow.

Standards: Darcy-Weisbach · Colebrook-White (turbulent)

Frequently asked questions

How do I use the Manning Open-Channel Flow (Full Pipe)?

Enter entered inputs with units as labeled, read each output with its substituted formula, then verify against datasheets and field readings before acting.

Is this result final?

Screening head-loss estimate. Verify roughness, fittings, and flow regime before construction.

Learn

How to interpret the result

Check gravity-flow capacity of a full pipe.

Checklist before you rely on it

  1. Confirm units match the input labels before trusting the result.
  2. Recompute at minimum and maximum operating cases, not just the design point.
Screening result for preliminary sizing only. Verify against the manufacturer datasheet and applicable standard before procurement or construction.

Related calculators

Workspace

Save this calculation to your workspace

Save this calculation to your private workspace: keep inputs + result, compare scenarios side by side, and export a report with substituted formulas.

  • Save projects — return to inputs, result, and report.
  • Compare scenarios — see which option holds margin.
  • Export report — PDF/CSV with formulas shown.

Sign in or create an account to save this calculation.