Orifice and Venturi Flow: Reading dP the Right Way

Read flow from differential pressure with a calibrated factor Q = C sqrt(dP/rho), then verify beta, straight runs, and density compensation.

Metering

Read flow from differential pressure with a calibrated factor Q = C sqrt(dP/rho), then verify beta, straight runs, and density compensation.

Calibrate C from one trusted point

Run a known flow, record dP and density, and solve C = Q / sqrt(dP/rho). That single factor absorbs the discharge coefficient, beta, and tap geometry for screening use on the same run.

Beta and straight-run discipline

Keep diameter ratio beta in 0.2-0.75 and respect upstream/downstream lengths, adding a conditioner when pipe is short. Swirl and asymmetry bias the root reading far more than most expect.

Density and custody limits

Liquids need temperature correction; gases need compressibility and expansion factors. Screening with constant density is fine for operations, but money measurement follows ISO 5167 in full.

Formulas

dP to flow

Q = C x sqrt(dP / rho)

C from calibration; rho at flowing conditions.

Calibration

C = Q / sqrt(dP/rho)

One trusted point fixes C for the run.

Worked example

Water run at 25 kPa

Inputs: C 50; dP 25; rho 1000.

Calculation: Q = 50 x sqrt(0.025) = 7.91 m3/h.

Frequently asked questions

What is C?

Calibrated factor linking dP to flow for one meter run.

How much straight run?

Roughly 10-20D upstream and 5D downstream, plus conditioner if short.

Does density matter?

Yes for liquids; gases need compressibility and expansion corrections.