Result
Formula
Calculation logicAbout this calculator
What this calculator does
Pump affinity laws estimate how a point on the same pump’s performance curve shifts when rotational speed changes. This calculator applies the speed ratio r = N₂/N₁ to the reference flow, head, and shaft power; it does not find a new system operating point from a pump curve.

| Quantity | Speed relationship | Why the exponent differs |
|---|---|---|
Flow Q | Q₂ = Q₁ × r | At corresponding points, flow scales with impeller speed. |
Head H | H₂ = H₁ × r² | Head is energy per unit weight and scales with the square of fluid velocity. |
Shaft power P | P₂ = P₁ × r³ | Power follows flow × head when efficiency is treated as unchanged. |
The Hydraulic Institute Pump Fundamentals guide presents these relationships for speed changes at corresponding pump operating points and cautions that actual efficiency can change with speed and operating point; this calculator assumes the cubic shaft-power relation directly and has no second-speed efficiency input.
Worked speed reduction
For the defaults, the speed ratio is r = 2,400 / 2,900 = 0.8276. Starting from Q₁ = 100 m³/h, H₁ = 30 m, and P₁ = 11.67 kW:
Q₂ = 100 × 0.8276 ≈ 82.76 m³/hH₂ = 30 × 0.8276² ≈ 20.55 mP₂ = 11.67 × 0.8276³ ≈ 6.61 kW
The same speed reduction changes the predicted flow by about 17%, head by about 32%, and shaft power by about 43%. The different percentages follow from the different exponents, not from separate efficiency or system calculations.
Check the system duty before relying on the scaled point
The flow ratio describes corresponding points on the pump curves; the installed system usually operates where the pump curve meets the system resistance curve. The Hydraulic Institute’s pump/system curve explanation shows why this intersection sets actual duty. When speed changes, that intersection may not land at Q₁ × r, especially when the system has substantial static head. Use the manufacturer’s curves at both speeds and check the operating-point intersection; the system curve builder can help estimate how required head varies with flow.
Use the estimate for a first comparison when the pump, impeller diameter, liquid, and operating regime remain the same. It does not model impeller trimming, viscosity changes, efficiency variation, minimum-flow limits, motor loading, cavitation, or NPSH. Verify the scaled duty and equipment limits against manufacturer data before setting a drive speed.
Input and output variables
- N
- Speed ratio
- Q/H/P
- Q~N, H~N2, P~N3
Worked example
1420 to 1750 rpm (ratio 1.232): Q x1.232, H x1.519, P x1.871. Trim the impeller instead if the motor cannot take 87% more power.
Standards: HI 9.6.3 (NPSH margin) · Affinity laws
Frequently asked questions
How do I use the Pump Affinity Laws?
Enter entered inputs with units as labeled, read each output with its substituted formula, then verify against datasheets and field readings before acting.
Is this result final?
Preliminary pump screening. Confirm with manufacturer curves and NPSH tests.
Learn
How to interpret the result
Predict duty after VSD slowdown or trim.
Checklist before you rely on it
- Confirm units match the input labels before trusting the result.
Related calculators
Pumps
Compressor Polytropic Power
Polytropic head and shaft power.
Open calculatorPumps
NPSHa vs NPSHr Check
NPSHa screening with >= 1 m margin rule.
Open calculatorPumps
Pump Duty Point Solver
Pump-system curve intersection, closed form.
Open calculatorPumps
Pump Head and Power
Hydraulic power Ph = rho*Q*H/366972. Shaft = Ph/eff. Motor with 15% margin.
Open calculatorWorkspace
Save this calculation to your workspace
Save this calculation to your private workspace: keep inputs + result, compare scenarios side by side, and export a report with substituted formulas.
- Save projects — return to inputs, result, and report.
- Compare scenarios — see which option holds margin.
- Export report — PDF/CSV with formulas shown.
Sign in or create an account to save this calculation.